(PC200V)Medical/Hospital/ICU Handheld Multiple Parameters Vital Signs Monitor
Model:PC200V
Parameters:ECG/ETCO2+SPO2+NIBP+TEMP
Features:
1. The Smart exquisite handheld patient monitor
2. ECG:3/5 Leads, 3 waves
3. Accurate measurement inlow perfusion index
provide the parameter of the PI
4. Accurate measurement in all kind of extreme environment measurement such as neonatal and shock patients
5. NIBP adopt SAWAA(Self-Adaptive-Waveform-Amplitude-Adjust)algorithm and SAFD(Self-Adaptive-Fast-Deflation)algorithm
6. Easy operation by 4"color TFT screen and Up to 100users ID switch
7. Multiple vital signs measurement parameters for collocation optional
l 3/5 Leads ECG, NIBP, SPO2, TEMP
l NIBP, SPO2, TEMP, CO2
8. Two measurements mode:Spot,Monitoring
9. Data storage capabilities,support for historical data view and trend chart back to see
l In monitoring mode,can continuously record 48 hours of measurement data
l In spot mode,100users ID,each user can store 200sets data
10. Support audio and visual alarm,support to set alarm uper and lower limit values
11. Lithium ion battery power supply
Perfomance Specifications:
Display |
4" color TFT |
Resolution |
320*480 |
Indicator |
Alarm indicator,Power indicator |
Trace |
1 plethysmogram waveform |
Alarm |
Probe off,low power |
modes |
visual and audio |
Application |
Neonatal,pediatric and adult patients, Pets and Animals |
Parameters Performance:
ECG
Lead |
7 lead(R, L, F, N, C1 or RA, LA, LL, RL, V1) |
Lead mode |
I, II, III, aVR, aVL, aVF, V1, CAL |
Wave |
3 waves |
Gain selection |
0.25V/mV, 0.5V/mV, 1V/mV, 2V/mV |
Heart Rate |
Adult |
PED/NEO |
Range |
15-300 bpm |
15-350 bpm |
Accuracy |
+/- 1% or +/- 1bpm Bigger |
Resolution |
1bpm |
Sensitivity |
>200 uV( peak to peak ) |
Bandwidth |
Diagnostic |
0.05-100 Hz |
Monitor |
0.5-40 Hz |
Surgery |
1-20 Hz |
Stronger Filter |
5-20 Hz |
NIBP
|
Adult |
PED |
NEO |
SYS |
40~270mmHg |
40~200mmHg |
40~135mmHg |
MEAN |
20~230mmHg |
20~165mmHg |
20~105mmHg |
DIA |
10~210mmHg |
10~150mmHg |
10~95mmHg |
Pulse Rate Range:40~240bpm |
NIBP measurement accuracy |
±3mmHg |
Pulse rate measurement accuracy |
≤2%(≥100bpm)or 2beats/min(<100BPM) |
Independent software protection pressure |
Adult:300mmHg |
PED:240mmHg |
NEO:150mmHg |
Independent hardware protection pressure |
Adult:320-330mmHg |
PED:265-275mmHg |
NEO:160-165mmHg |
Oxygen Saturation(%SPO2)
Measurement Range |
Measure Range |
SPO2:0-100% |
PR:0-254BPM |
Perfusion index:0.05%-20% |
Accuracy Range |
SPO2 saturation:70-100% |
Pulse Rate:30-254BPM |
Perfusion Index:0.025-20% |
Measurement Accuracy |
SPO2 |
Adult(including pediatric):±2digit(70-100%) not defined(<70%) |
Neonate:±3digits not defined(<70%) |
On motion condition :±3digits |
Pulse Rate |
Adult(including pediatric):±3digits |
Neonate:±3digits |
On motion condition::±3digits |
Perfusion Index:0.05%-20% |
Resolution |
SPO2 saturation:1% |
Pulse Rate:1BPM |
TEMP
Measurement range |
25-45°C |
Resolution |
0.1°C |
Accuracy |
0.1°C |
Power Type: Lithium ion battery
Operation time: 8 hours for normal operation
PC100 Series products:
According Products:
-Pulse oximeter/Vital Sign Monitor(handheld/fingertip)
-Patient Monitor
-ECG machine(Electrocardiograph)
-OEM Patient Monitoring Modules
-Infusion/Syringe Pump
-HFNC Machine and CPAP Machine
-Veterinary products
View more products, click here: https://un-medical.en.made-in-china.com/