Animal Clinic/Hospital Use Veterinary Handhled Patient Sign Monitor
Model:PC100
Parameters:SPO2+TEMP+NIBP
Features:
1. The smart and exquisite handheld vital sign monitor
2. Accurate measurement in low perfusion index
3. Provide the parameter of the PI
4. Accurate measurement
5. NIBP adopt SAWAA(Self-Adaptive-Waveform-Amplitude-Adjust)algorithm and SAFD(Self-Adaptive-Fast-Deflation)algorithm
6. Easy operation by 3.5"color TFT screen and Up to 100users ID switch
7. Multiple vital signs measurement parameters for collocation optional
l NIBP,SPO2,TEMP
l SPO2,TEMP
l NIBP,TEMP
l SPO2,ETCO2
l SPO2,NIBP,ETCO2
8. Two measurements mode:Spot,Monitoring
9. Data storage capabilities,support for historical data view and trend chart back to see
l In monitoring mode,can continuously record 48 hours of measurement data
l In spot mode,100users ID,each user can store 200sets data
10. Support audio and visual alarm,support to set alarm uper and lower limit values
11. Lithium ion battery power supply
12. Optional charging dock
Perfomance Specifications:
Display |
3.5" color TFT |
Resolution |
320*480 |
Indicator |
Alarm indicator,Power indicator |
Trace |
1 plethysmogram waveform |
Alarm |
Probe off,low power |
modes |
visual and audio |
Application |
Neonatal,pediatric and adult patients |
Parameters Performance:
NIBP
|
Adult |
PED |
NEO |
SYS |
40~270mmHg |
40~200mmHg |
40~135mmHg |
MEAN |
20~230mmHg |
20~165mmHg |
20~105mmHg |
DIA |
10~210mmHg |
10~150mmHg |
10~95mmHg |
Pulse Rate Range:40~240bpm |
NIBP measurement accuracy |
±3mmHg |
Pulse rate measurement accuracy |
≤2%(≥100bpm)or 2beats/min(<100BPM) |
Independent software protection pressure |
Adult:300mmHg |
PED:240mmHg |
NEO:150mmHg |
Independent hardware protection pressure |
Adult:320-330mmHg |
PED:265-275mmHg |
NEO:160-165mmHg |
Oxygen Saturation(%SPO2)
Measurement Range |
Measure Range |
SPO2:0-100% |
|
|
Accuracy Range |
SPO2 saturation:70-100% |
Pulse Rate:20-254BPM |
|
Measurement Accuracy |
SPO2 |
Adult(including pediatric):±2digit(70-100%) not defined(<70%) |
Neonate:±3digits not defined(<70%) |
On motion condition :±3digits |
Pulse Rate |
Adult(including pediatric):±3digits |
Neonate:±3digits |
On motion condition::±3digits |
|
Resolution |
SPO2 saturation:1% |
Pulse Rate:1BPM |
CO2
Measurement range:
ETCO2:0-150mmHg(0-19.7%)(0-20kPa) RR:3-150BPM
Accuracy range:
ETCO2 Range |
Accuracy |
0-40mmHg |
±2mmHg |
41-70mmHg |
±5% of reading |
71-100mmHg |
±8% of reading |
101-150mmHg |
±10% of reading |
RR Accuracy:±1BPM
Payment