(PC200)Medical/Hospital/Handheld Multiple Parameters Vital Signs Monitor Patient Monitor
Model:PC200
Parameters:ECG+SPO2+NIBP+TEMP
Features:
1. The smart and exquisite handheld patient monitor
2. ECG:3/5 Leads, 3 waves
3. Accurate measurement in low perfusion index
4. Accurate measurement
5. NIBP adopt SAWAA(Self-Adaptive-Waveform-Amplitude-Adjust)algorithm and SAFD(Self-Adaptive-Fast-Deflation)algorithm
6. Easy operation by 4"color TFT screen and Up to 100users ID switch
7. Multiple vital signs measurement parameters for collocation optional
l 3/5 Leads ECG, NIBP, SPO2, TEMP
l NIBP, SPO2, TEMP, CO2
8. Two measurements mode:Spot,Monitoring
9. Data storage capabilities,support for historical data view and trend chart back to see
l In monitoring mode,can continuously record 48 hours of measurement data
l In spot mode,100users ID,each user can store 200sets data
10. Support audio and visual alarm,support to set alarm uper and lower limit values
11. Lithium ion battery power supply
Perfomance Specifications:
Display |
4" color TFT |
Resolution |
320*480 |
Indicator |
Alarm indicator,Power indicator |
Trace |
1 plethysmogram waveform |
Alarm |
Probe off,low power |
modes |
visual and audio |
Application |
Neonatal,pediatric and adult patients |
Parameters Performance:
ECG
Lead |
7 lead(R, L, F, N, C1 or RA, LA, LL, RL, V1) |
Lead mode |
I, II, III, aVR, aVL, aVF, V1, CAL |
Wave |
3 waves |
Gain selection |
0.25V/mV, 0.5V/mV, 1V/mV, 2V/mV |
Heart Rate |
Adult |
PED/NEO |
Range |
15-300 bpm |
15-350 bpm |
Accuracy |
+/- 1% or +/- 1bpm Bigger |
Resolution |
1bpm |
Sensitivity |
>200 uV( peak to peak ) |
Bandwidth |
Diagnostic |
0.05-100 Hz |
Monitor |
0.5-40 Hz |
Surgery |
1-20 Hz |
Stronger Filter |
5-20 Hz |
NIBP
|
Adult |
PED |
NEO |
SYS |
40~270mmHg |
40~200mmHg |
40~135mmHg |
MEAN |
20~230mmHg |
20~165mmHg |
20~105mmHg |
DIA |
10~210mmHg |
10~150mmHg |
10~95mmHg |
Pulse Rate Range:40~240bpm |
NIBP measurement accuracy |
±3mmHg |
Pulse rate measurement accuracy |
≤2%(≥100bpm)or 2beats/min(<100BPM) |
Independent software protection pressure |
Adult:300mmHg |
PED:240mmHg |
NEO:150mmHg |
Independent hardware protection pressure |
Adult:320-330mmHg |
PED:265-275mmHg |
NEO:160-165mmHg |
Oxygen Saturation(%SPO2)
Measurement Range |
Measure Range |
SPO2:0-100% |
PR:0-254BPM |
|
Accuracy Range |
SPO2 saturation:70-100% |
Pulse Rate:30-254BPM |
|
Measurement Accuracy |
SPO2 |
Adult(including pediatric):±2digit(70-100%) not defined(<70%) |
Neonate:±3digits not defined(<70%) |
On motion condition :±3digits |
Pulse Rate |
Adult(including pediatric):±3digits |
Neonate:±3digits |
On motion condition::±3digits |
|
Resolution |
SPO2 saturation:1% |
Pulse Rate:1BPM |
TEMP
Measurement range |
25-45°C |
Resolution |
0.1°C |
Accuracy |
0.1°C |
Power Type: Lithium ion battery
Operation time: 8 hours for normal operation
PC100 Series products:
According Products:
-Pulse oximeter/Vital Sign Monitor(handheld/fingertip)
-Patient Monitor
-ECG machine(Electrocardiograph)
-OEM Modules
-Infusion/Syringe Pump
-HFNC Machine and CPAP Machine
-Veterinary products
View more products, click here: https://un-medical.en.made-in-china.com/
Payment
Shipping
Contact: Yuki.Cai