Wuhan Union Medical PC100handheld Patient Monitor

Product Details
Customization: Available
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient Monitor
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Import & Export Mode
Have Own Export License
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DDP, FCA
  • Wuhan Union Medical PC100handheld Patient Monitor
  • Wuhan Union Medical PC100handheld Patient Monitor
  • Wuhan Union Medical PC100handheld Patient Monitor
  • Wuhan Union Medical PC100handheld Patient Monitor
  • Wuhan Union Medical PC100handheld Patient Monitor
  • Wuhan Union Medical PC100handheld Patient Monitor
Find Similar Products

Basic Info.

Model NO.
PC100
Certification
MSDS
Group
All
Screen
3.5 Inch
Inside Battery
3.7V,2000mAh
Bluetooth
Support
Transport Package
Carton
Specification
handheld
Trademark
UN OEM
Origin
Wuhan, China
HS Code
9018193010
Production Capacity
1000PC/Month

Product Description

(PC100) Neonate/pediatric/adult Handheld Pulse Oximeter 
Model:PC100
Specifications:

 
Display Mode 3.5" color LCD display
Size Volume 146*67*30mm   
Weight 250g
Built in battery 3.7V/2000mAh
Safety type internal power supply BF type
Charger Input AC :100-240VAC    
Output  DC: 2A mirco USB interface
Wuhan Union Medical PC100handheld Patient Monitor

Parameters Performance:

NIBP
  Adult PED NEO
SYS 40~270mmHg 40~200mmHg 40~135mmHg
MEAN 20~230mmHg 20~165mmHg 20~105mmHg
DIA 10~210mmHg 10~150mmHg 10~95mmHg
Pulse Rate Range:40~240bpm
NIBP measurement accuracy ±3mmHg
Pulse rate measurement accuracy ≤2%(≥100bpm)or 2beats/min(<100BPM)
 
Independent software protection pressure
Adult:300mmHg PED:240mmHg NEO:150mmHg
Independent hardware protection pressure
Adult:320-330mmHg PED:265-275mmHg NEO:160-165mmHg

Oxygen Saturation(%SPO2)
 
Measurement Range SPO2 : 0-100%
PR  : 0-254bpm
Perfusion index : 0.2%-20%
Measurement Accuracy
SPO2  :70%-700%  ±2%  ;<70% undefined
PR: ±2



TEMP

Measurement Range:25-45°C
Resolution:0.3°C
Accuracy:0.3°C


Wuhan Union Medical PC100handheld Patient MonitorWuhan Union Medical PC100handheld Patient MonitorWuhan Union Medical PC100handheld Patient MonitorWuhan Union Medical PC100handheld Patient MonitorWuhan Union Medical PC100handheld Patient MonitorWuhan Union Medical PC100handheld Patient Monitor



Wuhan Union Medical PC100handheld Patient Monitor


Payment

Wuhan Union Medical PC100handheld Patient Monitor


Shipping


Wuhan Union Medical PC100handheld Patient Monitor

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More