(PC200)Medical/Hospital Handheld Multiple Parameters Vital Signs Monitor Patient Monitor
Model:PC200
Parameters:ECG+SPO2+NIBP+TEMP
Features:
1. The smart and exquisite handheld patient monitor
2. ECG:3/5 Leads, 3 waves
3. Accurate measurement in low perfusion index
4. Accurate measurement
5. NIBP adopt SAWAA(Self-Adaptive-Waveform-Amplitude-Adjust)algorithm and SAFD(Self-Adaptive-Fast-Deflation)algorithm
6. Easy operation by 4"color TFT screen and Up to 100users ID switch
7. Multiple vital signs measurement parameters for collocation optional
l 3/5 Leads ECG, NIBP, SPO2, TEMP
l NIBP, SPO2, TEMP, CO2
8. Two measurements mode:Spot,Monitoring
9. Data storage capabilities,support for historical data view and trend chart back to see
l In monitoring mode,can continuously record 48 hours of measurement data
l In spot mode,100users ID,each user can store 200sets data
10. Support audio and visual alarm,support to set alarm uper and lower limit values
11. Lithium ion battery power supply
Perfomance Specifications:
Display |
4" color TFT |
Resolution |
320*480 |
Indicator |
Alarm indicator,Power indicator |
Trace |
1 plethysmogram waveform |
Alarm |
Probe off,low power |
modes |
visual and audio |
Application |
Neonatal,pediatric and adult patients |
Parameters Performance:
ECG
Lead |
7 lead(R, L, F, N, C1 or RA, LA, LL, RL, V1) |
Lead mode |
I, II, III, aVR, aVL, aVF, V1, CAL |
Wave |
3 waves |
Gain selection |
0.25V/mV, 0.5V/mV, 1V/mV, 2V/mV |
Heart Rate |
Adult |
PED/NEO |
Range |
15-300 bpm |
15-350 bpm |
Accuracy |
+/- 1% or +/- 1bpm Bigger |
Resolution |
1bpm |
Sensitivity |
>200 uV( peak to peak ) |
Bandwidth |
Diagnostic |
0.05-100 Hz |
Monitor |
0.5-40 Hz |
Surgery |
1-20 Hz |
Stronger Filter |
5-20 Hz |
NIBP
|
Adult |
PED |
NEO |
SYS |
40~270mmHg |
40~200mmHg |
40~135mmHg |
MEAN |
20~230mmHg |
20~165mmHg |
20~105mmHg |
DIA |
10~210mmHg |
10~150mmHg |
10~95mmHg |
Pulse Rate Range:40~240bpm |
NIBP measurement accuracy |
±3mmHg |
Pulse rate measurement accuracy |
≤2%(≥100bpm)or 2beats/min(<100BPM) |
Independent software protection pressure |
Adult:300mmHg |
PED:240mmHg |
NEO:150mmHg |
Independent hardware protection pressure |
Adult:320-330mmHg |
PED:265-275mmHg |
NEO:160-165mmHg |
Oxygen Saturation(%SPO2)
Measurement Range |
Measure Range |
SPO2:0-100% |
PR:0-254BPM |
|
Accuracy Range |
SPO2 saturation:70-100% |
Pulse Rate:30-254BPM |
|
Measurement Accuracy |
SPO2 |
Adult(including pediatric):±2digit(70-100%) not defined(<70%) |
Neonate:±3digits not defined(<70%) |
On motion condition :±3digits |
Pulse Rate |
Adult(including pediatric):±3digits |
Neonate:±3digits |
On motion condition::±3digits |
|
Resolution |
SPO2 saturation:1% |
Pulse Rate:1BPM |
TEMP
Measurement range |
25-45°C |
Resolution |
0.1°C |
Accuracy |
0.1°C |
Power Type: Lithium ion battery
Operation time: 8 hours for normal operation
Series Products:
Feedbacks:
Company Introduction:
Wuhan Union Medical Technology Co., Ltd, a company specializes in patient monitoring solutions, which started in 2013.
We can offer you a variety of module platforms to integrate into your monitoring system. We are dedicating in and supplying all kinds of OEM modules of patient monitoring system.
Meanwhile, we are selling patient monitor, ECG machine, pulse oximeter, handheld vital signs monitor, handheld ETCO2 monitor, wireless capnograph, anesthesia multigas monitor, accessories of patient monitor, infusion pump, syringe pump, AED, defibrillator, infusion pump, syringe pump, ultrasound, veterinary equipments, etc. Please feel free to contact us if you are interested.
We will always try our best to offer you the best product & service.
Payment
Shipping
Contact: Yuki.Cai