• High Performance Veterinary Animal Use Internal Sidestream End-Tidal Multi-Gas Module
  • High Performance Veterinary Animal Use Internal Sidestream End-Tidal Multi-Gas Module
  • High Performance Veterinary Animal Use Internal Sidestream End-Tidal Multi-Gas Module
  • High Performance Veterinary Animal Use Internal Sidestream End-Tidal Multi-Gas Module
  • High Performance Veterinary Animal Use Internal Sidestream End-Tidal Multi-Gas Module
  • High Performance Veterinary Animal Use Internal Sidestream End-Tidal Multi-Gas Module

High Performance Veterinary Animal Use Internal Sidestream End-Tidal Multi-Gas Module

Model Number: AG900
Material: Metal, Plastic
Quality Certification: CCC
Safety Standard: GB2626-2006
Agent Threshold: Agent 0.13vol%
Sample Rate: 50ml/Min
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AG900
Rr
3-150 Brpm
Power Source
Manual
After-Sale Service
Return and Replacement
Initialization Time
20s
Interface
RS232
Power Consumption
Less Than 2W
Voltage
5V DC
Production Capacity
5000PC/Month

Product Description

Product Description
 
State-of-the-art Non-dispersive infrared (NDIR) technology
Co2 N2O and anesthesia multigas monitoring
Real-time and continuous measurement of gas concentrations and respiratory rate
Sample rate low to 50 mL/min
Barometer pressure and temperature compensation
Fast warmup time ensures full accuracy within 2 minutes
Low power consumption less than 2W

 
High Performance Veterinary Animal Use Internal Sidestream End-Tidal Multi-Gas ModuleHigh Performance Veterinary Animal Use Internal Sidestream End-Tidal Multi-Gas ModuleHigh Performance Veterinary Animal Use Internal Sidestream End-Tidal Multi-Gas ModuleHigh Performance Veterinary Animal Use Internal Sidestream End-Tidal Multi-Gas ModuleProduct Introduction

The AG900 series multigas analyzer is the ideal low sampling-rate anesthesia solution for your patient monitoring system. AG900
can show an accurate gas concentration with all respiration rates up to 150 breaths per minute. Advanced technology enables AG900
to provide accurate measurement of CO2, N2O, anesthetic agents gas, respiration rate, inspiration time and expiration time. With a
sampling-rate low to 50 mL/min, AG900 is ideal for use on adult, pediatric and infant patients; patients undergoing procedural
sedation; and short- term monitoring of intubated patients.


Specification
Transducer Type AG900 series multigas analyzer
Sample Rate 50 mL/min, ±10mL/min
Principle of Operation Non-dispersive infrared (NDIR) ,no moving parts
Initialization Time 20 sec, full specifications within 60 sec
Calibration No routine user calibration required
Compensation Automatic for atmospheric pressure, temperature
Rise Time Co2 < 200ms, N2O,AA < 350ms
Respiratory Rate Range 3 to 150 Breaths Per Minute (BPM)
Accuracy ±1 breath
 
Breath Detect Adaptive threshold, minimum 1% Co2 change
Agent Threshold Agent 0.15 vol%
Measurement Accuracy Gas type Range accuracy
Co2 0 - 10% ±(0.2 vol% +2% of reading)
10 -15% ± (0.3 vol% +2% of reading)
N2O 0 - 100% ± (2vol% +2% of reading)
ISO 0 - 6% ± (0.2vol% +2% of reading)
ENF 0 - 6% ± (0.2vol% +2% of reading)
SEV 0 - 8% ± (0.2vol% +2% of reading)
Interface RS-232 operating at 9600 bps
Voltage Requirements 5.0 VDC ±5%
Power Consumption Less than 2.0 Watts typical
Temperature and Humidity Operating: 0 C to 40 C, 10 to 90% RH, non-condensing
Storage: -40 C to 70 C,
Size;Weight 96 x 57.5 x 30 mm; 110 g
High Performance Veterinary Animal Use Internal Sidestream End-Tidal Multi-Gas Module

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now